Glycol Dehydration
Water vapour can be removed from gas streams by glycol absorption in a contactor tower to reduce the water dewpoint to pipeline specification. The water rich glycol is then regenerated with heat and depending on required purity, sparging or stripping gas. Maloney Industries' glycol dehydration systems typically consist of an absober, gas/glycol exchanger, reboiler, accumulator, still column, lean/rich glycol exchanger, flash tank, filter and circulation pumps. The absorber is designed to use either bubble cap trays, valve trays, or structured packing for gas/glycol contacting. |
||